Incineration vs gasification vs plasma: which waste treatment is best?

Short answerNo conventional method treats 100% of mixed waste. Grate incineration is proven but leaves about a quarter of the input as ash, part of it hazardous. Gasification and plasma usually need pre-sorted, uniform feed. A molten slag bath at 1300 °C accepts unsorted waste and leaves only 10–15% inert glassy slag that can be used in construction.

The four technologies at a glance

ParameterGrate incinerationGasification, pyrolysisPlasmaNullogen molten slag bath
Process temperature850–1100 °C; EU law requires at least 850 °C for 2 s1Typically 700–1000 °C in the reactorAbove 1200 °C, much hotter at the torch1300 °C in the melt, gas held at least 2 s
Pre-sortingNot required, but wet or variable waste lowers efficiencyUsually required: feed is prepared as RDFUsually required for stable operationNot required, wet sludge accepted
Solid residueBottom ash, about 20–25% of input, plus fly ashChar and ash, depends on processVitrified slag10–15% glassy slag
Residue statusFly ash is hazardous waste; bottom ash needs treatment before reuseOften landfilledInertInert, no organics, does not absorb water
Toxic gasesDioxins controlled by flue-gas cleaningTar and syngas cleaning are criticalLowExcess oxygen and 1300 °C prevent dioxin formation
Main limitationAsh disposal costFeed preparation, limited MSW track recordHigh electricity use of the torchesFirst commercial waste plants in development

How does grate incineration work?

Waste is burned on a moving grate at 850–1100 °C, and the heat raises steam for electricity. It is the most widely used waste-to-energy method in the world and handles mixed municipal waste. Its weak point is residue: about a fifth to a quarter of the input remains as bottom ash, and the fly ash captured in the filters is classed as hazardous waste that has to be stabilised and landfilled.

Is gasification better than incineration?

Gasification heats waste with limited oxygen to make a combustible syngas instead of burning it directly. In theory this gives higher efficiency. In practice, municipal waste must first be shredded and sorted into refuse-derived fuel, and tar in the syngas makes gas cleaning difficult. Few gasification plants run on mixed municipal waste at commercial scale.

What is plasma gasification, and why is it rare?

Plasma torches reach extreme temperatures and turn the inorganic part of waste into vitrified slag. The residue is inert, but the torches consume a large share of the electricity the plant produces, and the equipment is expensive to run and maintain. That is why plasma is mostly used for small volumes of hazardous waste.

How is the molten slag bath different?

Waste is fed continuously onto a bath of molten slag at 1300 °C. Oxygen-enriched blast is injected below the melt surface, so the waste is mixed into the slag and heated almost instantly. Organic matter oxidises completely, chlorine leaves as HCl before dioxins can form, and inorganic matter melts into slag that is tapped from the furnace. The hot gas goes to a boiler for heat and electricity. See how the furnace works.

Which technology leaves the least waste for landfill?

Technologies that melt the residue, plasma and the molten slag bath, leave the least. Their slag is glassy, does not leach and can replace gravel or part of the cement in construction products, so nothing has to go to landfill. Grate incineration and most gasification plants still send ash to landfill. Compare ash and slag.

Frequently asked questions

Does the molten slag bath need sorted waste?

No. Household, industrial, medical, toxic and old landfill waste can be loaded into the same unit, including waste with very high moisture such as sewage sludge.

How much residue is left after treatment?

Slag makes up 10–15% of the initial mass of municipal waste. Grate incineration typically leaves 20–25% bottom ash plus hazardous fly ash.

Why do dioxins not form at 1300 °C?

Dioxins form from chlorine and organic fragments when hot gas cools slowly. With excess oxygen at 1300 °C, organics are fully oxidised and chlorine leaves as HCl, which is captured in standard gas cleaning.

Is the slag safe to use in construction?

In laboratory tests the slag was non-toxic, did not absorb water and lost 0.00% of its mass in sulfuric acid. It can be used for concrete products, blocks, tiles, gravel and alternative cement.

Related questions

Which technology fits your waste?

Send us your waste volumes and composition, and we will prepare a plant configuration.

Request for proposal
Sources
  1. Directive 2010/75/EU on industrial emissions, Article 50: gas temperature of at least 850 °C for two seconds.
  2. Nullogen laboratory tests of MSW slag and process data.
Nullogeninfo@nullogen.com© 2026 Nullogen